The BELSORP MAX II analyzer allows for comprehensive surface characterization such as micropore analysis by measuring adsorption isotherms from extremely low pressure, or hydrophilicity/hydrophobicity by water vapor adsorption.
Measurement principle | Volumetric method + AFSM™ |
Adsorption gas | N2, Ar, Kr, CO2, H2, O2, CH4, NH3, butane, and other non-corrosive gases |
Adsorption vapor | H2O, MeOH, EtOH, C6H6, and other non-corrosive vapor |
Gas ports | 2 ports (optional: 7 ports; 12 ports max.) |
Number of measurements (High Accuracy mode) |
BELSORP MAX II & MAX II HV: Max. 4 ports simultaneously (3 ports in High Accuracy mode) BELSORP MAX II HP: Max. 3 ports simultaneously (2 ports in High Accuracy mode) |
Measurement range (specific surface) | 0.01 m2/g and above (N2) 0.0005 m2/g and above (Kr) (depending on sample density) |
Pore size distribution (Diameter) | 0.35 - 500 nm |
Low pressure isotherm | BELSORP MAX II & MAX II HP: p/p0 = 10^-8 (N2 @77K, Ar @87K) BELSORP MAX II HV: p/p0 = 10^-6 (N2 @77K, Ar @87K) |
Vapor adsorption | BELSORP MAX II & MAX II HP: p/p0 = ~0.95 @40°C BELSORP MAX II HV: p/p0 = ~0.95 @70°C |
High pressure gas sorption | BELSORP MAX II HP: 900 kPa (Port 2) |
Pressure transducer (1 MPa: 7500 Torr) | BELSORP MAX II HP: 1 unit |
Pressure transducer (133 kPa: 1000 Torr) | BELSORP MAX II: max. 6 units BELSORP MAX II HP: 5 units BELSORP MAX II HV: 6 units |
Pressure transducer (1.33 kPa: 10 Torr) | BELSORP MAX II: max. 4 units BELSORP MAX II HP: 3 units BELSORP MAX II HV: 4 units |
Pressure transducer (0.0133 kPa: 0.1 Torr) | BELSORP MAX II: max. 3 units BELSORP MAX II HP: 2 units |
Thermostatic air oven | BELSORP MAX II & MAX II HP: 50°C BELSORP MAX II HV: 80°C |
Vacuum gage / pump | Turbo molecular pump + rotary pump |
Sample tube | Standard tube, approx. 1.8 cm3 (optional: 5 cm3) |
Dewar vessel | Volume: 3.8 l Holding time: 80 h |
Pretreatment heater | 50 - 550°C |
Water bath | -10 - 70°C |
Analysis software BELMaster™ 7 | Adsorption isotherm, BET specific surface area I type (ISO9277), BET automatical analysis, Langmuir supecific surface area, BJH, DH, CI, INNES method, t-plot |
Analysis software BELMaster™ 7 cont. | HK, SF, CY method, NLDFT / GCMC (OP BELSim™), MP method, Dubinin-Astakhov method, Difference adsorption isotherm, molecular probe, adsorption rate analysis (opt.) |
Dimensions (W x H x D) | 650 x 1020 x 680 mm |
Weight (main body) | 120 kg |
Utility - Gas | He, adsorption gas: 0.1MPa Joint: 1/8" Swagelok joint |
Utility - Power | Main unit: AC 100 - 120 V / 200 - 240 V, 1500 W (incl. rotary pump), 50 / 60 Hz Heater: AC 100 - 120 V / 200 - 240 V, 900 W, 50 / 60 Hz |
Environmental conditions | Temperature: 10 - 30°C Humidity: 20 - 80% RH |
CE certified | yes |