Microtrac’s synchronous size and shape analyzer, Sync, integrates the world’s leading laser diffraction technology with the world’s leading dynamic image analysis technology – Same bench, same sample, same run, same flow cell, same user interface. Users can now get their tried and true particle size distribution together with particle morphology in a single, easy to use graphical user interface.
Particle Size Analysis with LD Method
In Microtrac's technology two fixed photoelectric detectors with logarithmically spaced segments are placed at correct angles for optimal scattered night detection from 0.02 to 163 degrees using 151 detector segments. That improves consistent and repeatable particle size distribution and shape analysis.
Particle Shape Analysis with DIA Method
Particles in a flowing stream, back lit by a high speed strobe light, are photographed by a high resolution digital camera to
create a video file of images for the flowing particles. The pixel size of the camera and the number of pixels in the image are used to measure a large number of particle size and shape parameters, along with a measure of transparency.
FlowSync: Wet Delivery System
The FlowSync’s automated filling, de–aerating, pre-circulating and circulating operation means each sample is handled with a consistency that improves the repeatability of particle size distribution and shape data.
A separate fill pump allows the user to connect to any water or solvent source. An in-line ultrasonic probe with variable power disperses agglomerated materials to ensure consistent sample dispersion during measurements. The FlowSync’s fluid dynamics feature a built-in turbulence to ensure that all particles are moving constantly within the flow, negating the need for an external stirrer.
TurboSync: Dry Delivery System
The TurboSync’s primary function is to deliver a properly dispersed sample to the measuring cell allowing for consistent and repeatable particle size analyses of dry powders.
Compressed air and flow conditions settings allow the operator to achieve optimal dispersion usually associated with fluid dispersal systems for highly agglomerated materials such as alumina. Dispersion conditions can be fine-tuned for measurement of the most fragile materials.
Sample volumes can be as small as 0.1 cc. Ideal for applications where sample is expensive to produce or produced in small volumes.
Features
Key Benefits
Measuring Range |
10nm - 4000µm |
Precision |
Spherical Glass Beads D50 = 642 microns, Precision as CV = 0.7% Spherical Glass Beads D50 = 57 microns, Precision as CV = 1.0% Spherical Latex Beads D50 = 0.4 microns, Precision as CV = 0.6% |
Laser Class |
Red 780 nm, Blue 405 nm - Class 1 Laser Product per 21 CFR 1040.10 & IEC60825-1 |
Laser Power |
Red Laser 3mW nominal; Blue Lasers 4-8 mW nominalmW |
Detection System |
Two fixed photo-electric detectors with logarithmically spaced segments are placed at correct angles for optimal scattered light detection from 0.02 to 163 degrees using 151 detector segments. |
Data Handling |
Volume, Number and Area distributions as well as percentile and other summary data. Data is stored in ODBC format in encrypted Microsoft Access Databases to ensure compatibility with external statistical software applications. Data integrity may be ensured using FDA 21 CFR Part 11 compliant security features including password protection, electronic signatures and assignable permissions. |
Typical Analysis Time |
10 to 30 seconds |
Electrical |
AC input: 90 – 264 VAC, 47 - 63 Hz, single phase |
Power Consumption |
25W nominal, 50W Max., depending on options installedolarak en fazla 50W. |
Environmental |
Temperature: 5 to 40 Degrees C. (50 to 95 Degrees F) Humidity: 90% RH, non- condensing maximum Storage Temperature: -10 to 50 Degrees C ( 14 to 122 Degrees F )(Dry only) Pollution: Degree 2 |
Compliance |
ISO 13320 Laser Diffraction ISO 13322 Imaging |
Image Analysis |
5.2-megapixel (2560 x 2048), 22 fps at max res.22fps |
Wet Operation |
Volume: 200ml nominal Flow Rate: 0 to 65 ml/sec with water Inlet Pressure: 50 psig (345 kPa) maximum |
Dry Operation |
100 psi (689 kPa) maximum pressure 5 CFM (8.5 m3/h) at 50 psi (345 kPa) minimum flow rate Free of dry contaminants, moisture and oil. |
Vacuum |
Vacuum must meet or exceed 50 CFM (85 m3/h) |
Physical Specifications |
Case Material: Impact resistant plastic Exterior surfaces are finished with corrosion resistant paint or plating Chemical Compatibility: Class I |
Dimensions |
18.1H x 32.3W x 19.7D in (46H x 82W x 50D cm) |
Weight |
FlowSync: 43lbs (19.5kg) TurboSync: 30lbs (13.6kg) Sync: 50.8lbs (23.06kg)3.6kg |